Ekotex Sofia: Products

Panel metal filters (de-oiling)

Back to the category

APPLICATION :

Pre-filters, G2 class, used as a first-stage of filtration for applications in high-temperature processes.

Allowable case dimensions: frame height – by order available with sizes from 20 mm to 98 mm.

Frame dimension width x length – by order available with sizes up to 1500 mm x 1500 mm.

TECHNICAL SPECIFICATIONS

Properties

 

Filter class EN 779

G2

Eurovent DIN 24185

EU 2

Am ( % )

60- 70

Final Pressure Drop ( Pa )

250

Max Operating Temperature o C

200

Frame

Galvanized Steel,Stainless Steel

Media

Multilayer Galvanized Mesh, Stainless Steel Mesh

 

Wesheable

Filter stage

1

dim

Filter class

media

Airflow capacitym3/h @ resistence ( Pa )

W x H x D

En 779

Area m2

2,5 m /s

3,2 m /s

592x592x24

G2

0,37

3400

35

4200

45

592x592x48

G2

0,8

3400

25

4200

35

592x592x98

G2

1,6

3400

15

4200

25

Gallery